Rated
Volt |
Voltage
Range |
Freq |
Input
Power |
Ref.
Speed |
Max.Airflow |
Max.Static Pressure |
Noise
Level |
PQ |
UL |
Model No |
VAC |
VAC |
Hz |
Watt |
RPM |
CFM |
m3/min |
Inch/H2O |
mm |
db(A) |
|
|
MK150AN11-1xx (MS)
|
115
|
100~120
|
50/60
|
40/32
|
2700/3100
|
210/240
|
5.9/6.8
|
0.53/0.57
|
13.46/14.48
|
53/59
|
|
£
|
MK150AN22-1xx (MS)
|
230
|
200~240
|
50/60
|
40/32
|
2700/3100
|
210/240
|
5.9/6.8
|
0.53/0.57
|
13.46/14.48
|
53/59
|
|
£
|
MK150AN22-1xx (MS)(240)
|
240
|
200~240
|
50/60
|
40/32
|
2700/3100
|
210/240
|
5.9/6.8
|
0.53/0.57
|
13.46/14.48
|
53/59
|
|
£
|
|
The stated airflow, air pressure, noise levels are measured with housing orifice dia.: impeller Φ +1~1.5mm, at distance: approx. height of impeller + motor frame. The optimal operating data can only be depended on the installation conditions.
** = "WB" for wire lead type Ball bearing, or "TB" for terminal type Ball bearing
100, 200, 240V or special voltages 12, 24, 28,
38, 42, 48, 380~440~480... 50/60Hz, & dual voltage version
available on request.
Dual speed High/Medium 1/2, High/Low 1/3, Medium/Low 2/3, Low/extra Low 3/4 or triple speed 1/2/3 available
on request.
Sinwan reserves the right to change data and improve
electrical or mechanical design without notice,
data tolerance +-10%
|