‧AC‧MK150AN (MS)

Dia.145x38mm / 5.7inch
240~210 CFM
Metal Impeller, Outer Rotor, Capacitor Induction
  Rated
Volt
Voltage
Range
Freq Input
Power
Ref.
Speed
Max.Airflow Max.Static Pressure Noise
Level
PQ UL
Model No VAC VAC Hz Watt

RPM

CFM m3/min Inch/H2O mm db(A)    
MK150AN11-1xx (MS) 115 100~120 50/60 40/32 2700/3100 210/240 5.9/6.8 0.53/0.57 13.46/14.48 53/59 £
MK150AN22-1xx (MS) 230 200~240 50/60 40/32 2700/3100 210/240 5.9/6.8 0.53/0.57 13.46/14.48 53/59 £
MK150AN22-1xx (MS)(240) 240 200~240 50/60 40/32 2700/3100 210/240 5.9/6.8 0.53/0.57 13.46/14.48 53/59 £
  • The stated airflow, air pressure, noise levels are measured with housing orifice dia.: impeller Φ +1~1.5mm, at distance: approx. height of impeller + motor frame. The optimal operating data can only be depended on the installation conditions.
  • ** = "WB" for wire lead type Ball bearing, or "TB" for terminal type Ball bearing
  • 100, 200, 240V or special voltages 12, 24, 28, 38, 42, 48, 380~440~480... 50/60Hz, & dual voltage version available on request.
  • Dual speed High/Medium 1/2, High/Low 1/3, Medium/Low 2/3, Low/extra Low 3/4 or triple speed 1/2/3 available on request.
  • Sinwan reserves the right to change data and improve electrical or mechanical design without notice, data tolerance +-10%
  •  
      Motor Type: Capacitor Induction motor, Outer rotor
      Burnout Protection: Thermally protected
      IP Protection: IP56
      Frame: -
      Impeller: Metal 6 blades
      Bearing: Two ball bearings
      Rotation: CCW seen on rotor
      Connection: Wire lead
      Weight: 610g
      Dielectric Strength: Over 1 min.at 1,500 VAC
      Insulation Resistance: 100Mega ohm min. at 500VDC
      Signal Output: Optional: R/D alarm output, Tachometer output
      Operating Temp: -20~+70C
      Storage Temp: -40C~+80C
      Life Expectancy: L10 70K hours at 25C

     

    Metal Fan Guard
    GK172-3UT